2.2.1 Direct Systems
The water that will be used as domestic hot water is circulated directly into the collectors from the storage tank (typically a hot water heater which will back up the solar heating).
There are two types of direct systems: draindown and recirculating. In both systems, a controller will activate a pump when the temperature in the collectors is higher than the temperature in the storage tank.
The draindown system includes a valve that will purge the water in the collectors when the outdoor temperature reaches 38 degrees. When the temperature is higher than 38 degrees and the collectors are hotter than the storage tank, the valve allows the system collectors to refill and the heating operation resumes.
The recirculating system will pump heated water from the storage tank through the collectors when the temperature drops to 38 degrees.
These two systems have serious drawbacks. The draindown valves can fail in a draindown system and the result can be the expensive breakage of the solar collectors. The draindown valve will typically sit unused for a very long time and then will need to work the first time without failing. The cycling of air and water in a draindown system collectors as a result of periodically draining down (thereby emptying the collectors) can cause a buildup of mineral deposits in the collectors and reduce their efficiency. The recirculating system circulates buildup from potable water heated from the storage tank through collectors during potential freeze conditions and effectively cools the water (wasting energy).
2.2.2 Indirect Systems
Systems that use antifreeze fluids need regular inspection (at least every 2 years) of the antifreeze solution to verify its viability. Oil or refrigerant circulating fluids are sealed into the system and will not require maintenance. A refrigerant system is generally more costly and must be handled with care to prevent leaking any refrigerant.
An indirect system that exhibits effectiveness, reliability, and low maintenance is the drainback system (see Figure 1 on next page).
The drainback system typically uses distilled water as the collector circulating fluid.
The collectors in this system will only have water in them when the pump is operating. This means that in case of power failure as well as each night, there will be no fluids in the collector that could possibly freeze or cool down and delay the startup of the system when the sun is shining.
This system is very reliable and widely used. It requires that the collectors are mounted higher than the drainback tank/heat exchanger. This may be impossible to do in a situation where the collectors must be mounted on the ground.
An indirect or direct system can be used for heating swimming pools and spas. Lower cost unglazed (no glass cover) collectors are available for this purpose.